CHAPTER 7 ANALOG INPUTS
32
33
Analog Inputs.
EVO4 has five 12 bits analog inputs, recorded
up to 1000 times per second each.
You can connect 0-5 Volt signals, ratiometric
potentiometers, pressure sensors, thermo-re-
sistances and K-type thermocouples.
Please, follow the steps:
Connect the sensor to the desired input
Enable the channel in the Channels table
Select the proper sensor type; sensors of
many different types are properly handled,
such a: Temperature sensors, Pressure Sen-
sors, Potentiometers, Generic Sensors.
Set the sampling frequency
Set the unit of measure.
EVO 4
n
Temperature sensors
n
Pressure Sensors
n
Potentiometers
n
Generic Sensors
K thermocouples
Thermo-PT100 resistors
Temperature sensors VDO
VDO 40-120 ° C
VDO 50-150 ° C
VDO 60-200 ° C
MSI 0-2 bar
MSI 0-5 bar
MSI 0-10 bar
MSI 0-2000 psi
Distance
Zero-based
Zero Central
0-50 mV
0-500
0-5 V
1
2
3
4
5